Spa Operator’s Guide
Sec1:20
(XM.ce) WIRING CONNECTIONS
Electrical Wiring
Case 1
The installation of electrical circuit jumpers is needed in certain input
supply confi gurations.
Use uncut jumper as supplied in the case of an input supply wiring,
single-phase 1 x 230 VAC (32 A max).
Case 2
In the case of an input supply wiring for a dual phase system
2 x 230 VAC (16 A max), you’ll need to cut off a portion of the jumper
piece.
Proceed as follows:
Use a pair of pliers to fi rmly hold the upper half of the metal jumper, then
break off the other half.
Case 3
Please note that in a 3-phase system 1 x 230 VAC (3 x 16A)
No jumper installation is required.
Note: IMPORTANT Safely dispose of the discarded portion in
accordance with the local waste disposal legislation in force.